BA6Project Solutions
Solar + battery storage + medium-voltage equipment

Power for sites the grid doesn't reach.

BA6 Project Solutions engineers and sources off-grid solar, battery storage and transformer systems for EPCs, developers and data-centre owners. We write the specification, price the equipment, structure the financing and stay until it is energized.

SOLAR PV4 x 125 kW inverters 415Y/240 Vungrounded BATTERY STORAGEPCS + EMS 415Y/240 Vungrounded 2000 kVAYyn0 isolation K-8 / IP55 / tertiary DATA CENTREoff-grid load 415Y/240 V X0
FIG. 1 Typical BA6 package: ungrounded source side, grounded load side
Lane 1

Engineering services

Independent technical work for owners and EPCs who need the design, the spec and the numbers right before money is committed.

  • Electrical, mechanical, civil and structural design
  • Preliminary design and optimization
  • Procurement support and IFC drawing sets
  • Owner's and independent engineering, project monitoring
Lane 2

Systems & equipment

Sourced, specified and delivered as a package, so the PV, storage, EMS and medium-voltage pieces are designed to work together.

  • Battery containers and all-in-one cabinets
  • PV inverters and plant controls
  • Dry-type and oil-filled transformers
  • Skids, enclosures and protection
Lane 3

Financial services

The same team that designs the project builds the model and structures the capital that pays for it.

  • Financial modeling
  • Equity financing
  • Debt financing
  • Tax credit transfers and preferred equity, US$20M to US$300M per deal
How we work

From first question to energized.

Scope

Load profile, voltage, grounding, site conditions. We write down what the system has to do.

Specify

A data sheet your engineer can review and a vendor can quote without guessing.

Source

Quotes compared line by line against the spec, with mismatches flagged before you order.

Support

Drawings, submittals, factory tests and commissioning, through to energization.

Where we work

Built for the hard sites.

Projects across the United States (Texas, Arkansas, Virginia, Nevada, California) and the Philippines.

01

Off-grid data centres

Solar and storage feeding a grounded load through an isolation transformer, with the fault current and grounding worked out up front.

02

Islands and cooperatives

Hybrid solar, battery and generator systems that cut diesel use where fuel is shipped in.

03

Industrial and C&I

Peak shaving, backup power and generator replacement behind the meter.

04

EPCs and developers

A specification and procurement partner for teams that build but don't want to guess at equipment.

Engineering services

Get the design right before you buy.

Most cost overruns on solar and storage projects start as an unclear specification. We write the spec, test the proposals against it, and give your engineer something concrete to approve.

Disciplines

Four disciplines under one roof.

Electrical

Power system design

Single-line diagrams, short-circuit and protection studies, grounding, cable and transformer sizing.

Mechanical

Equipment and enclosures

Cooling and ventilation, skid and container layout, equipment handling and access.

Civil

Site works

Grading, drainage, access roads, trenching and equipment pads.

Structural

Foundations and racking

PV racking and array foundations, equipment supports, wind and seismic loads.

Project lifecycle

From preliminary design to project monitoring.

Preliminary design and optimization

Layout, energy yield, battery sizing and cost, tuned together for the lowest cost per delivered kWh.

Procurement

Equipment specifications, RFQ packages, proposal comparison and clarifications.

IFC drawing sets

Issued-for-construction drawings across all four disciplines.

Owner's engineering

Technical representation for the owner through design, build and commissioning.

Independent engineering

Third-party review of design, equipment and performance for lenders and investors.

Project monitoring

Progress and performance tracking from construction through operation.

Specialist services

Feasibility

Sizing and budget

PV, battery energy and power, transformer rating and autonomy hours, with a budgetary price range.

Design

Specification

Equipment data sheets with every parameter stated: ratings, losses, sound, BIL, enclosure, terminations and tests.

Review

Proposal comparison

Vendor quotes checked line by line against your spec, with a plain list of mismatches to send back.

Owner's engineering

Procurement support

RFQ packages, clarifications, factory test witnessing and submittal review.

Grounding

System architecture

Grounded and ungrounded sources, separately derived systems, neutral paths, ground-fault detection.

Commissioning

Energization support

Check sheets, test review and punch-list tracking to a clean handover.

What you receive

Specification packageEquipment data sheet, status-tagged: set by the owner, estimated, or open for the engineer.
Review checklistOpen design decisions listed for your engineer of record, each with the reason it matters.
Quote comparisonSide-by-side table of each proposal against the spec, plus a draft reply to each vendor.
DrawingsAnonymized single-line diagrams for tender, so vendors can quote without client identifiers.
Systems & equipment

One package. Designed to work together.

We source the major pieces of a solar-plus-storage site and specify them as a system, so grounding, voltages and protection line up before anything ships.

Storage

Battery containers and cabinets

Containerized and all-in-one cabinet BESS with PCS and EMS, sized for power and autonomy.

Generation

PV inverters

Three-phase string inverters in the 100 to 125 kW class, matched to the site voltage and plant controller.

Medium voltage

Transformers

Dry-type isolation and step-up transformers, specified to IEC or IEEE.

Balance of plant

Switchgear, skids, enclosures

Skid bases, IP55 enclosures, double lug sets for phase-2 expansion, protection and metering.

Packages

PackageTypical scaleContents
Compact C&I100 kW to 1 MWPV inverters, battery cabinets with EMS, protection and metering
Site power1 to 5 MWPV, battery containers, isolation transformer, switchgear on skid
Off-grid campusAbove 5 MWEngineered to order, with generator integration and grounded load side
Financial services

A project that closes needs a model that holds up.

We build the financial model and help structure the capital, from equity and debt to tax equity. Because our engineers work on the same projects, the yield, capex and O&M in the model come from the design, not from a template.

Modeling

Financial modeling

Project cash-flow models with scenarios and sensitivities, including storage revenue from ancillary services and arbitrage, and system designs tuned for cost and payback.

Equity

Preferred equity

We advise on and arrange preferred equity, sponsor equity and co-investment structures, with investor materials and returns analysis for each class of capital.

Debt

Debt financing

Construction and term debt packages, lender-ready models, and independent engineering reports to support the credit case.

Tax equity

Tax credit transfers

We advise on and arrange the sale of tax credits for US projects, with the modeling behind pricing and terms, subject to current law and your tax adviser.

One team, one set of numbers.

Design to modelEnergy yield, equipment cost and O&M assumptions come directly from the engineering work.
Model to lendersModels are structured so a lender or investor can audit every input and trace it to a source.
Independent reviewOur independent engineers can review the technical case that supports the financing.
OptimizationResidential and C&I systems are sized for lowest cost and shortest payback; utility-scale systems for return on capital.
Deal sizeUS$20M to US$300M per financing
InstrumentsTax credit transfers and preferred equity
Our roleAdvisor and arranger
Applications and industries

Pick the problem. We'll size the system.

Application

Off-grid power

Sites with no grid, or a grid too weak to rely on. Solar and storage carry the load; a generator covers the long tail.

Application

Diesel displacement

Cut fuel burn by letting solar and batteries run the base load.

Application

Peak shaving

Flatten demand charges with a battery sized to the shape of your load.

Application

Grid services and arbitrage

Utility-scale and standalone batteries earning from ancillary services and price spreads.

Application

Backup and microgrids

Seamless transfer for critical loads, with the grid as one of several sources.

Industry

Data centres

High, steady load with strict power quality. Grounding and harmonics (K-rated transformers) matter here.

Industry

Islands and electric cooperatives

Remote communities where fuel is expensive and outages are routine.

Industry

Mining, resorts, agriculture

Remote operations that run all day and pay a lot for fuel.

Industry

Manufacturing

Plants that need to ride through dips and cap peak demand.

Industry

Healthcare and cold chain

Backup power for critical load such as vaccine storage.

Industry

Research facilities

Reliable, clean power for labs and instruments.

Industry

Hotels and hospitality

Lower power bills and ride-through during outages.

Industry

Residential

Systems optimized for cost and short payback.

Rough sizing calculator

Budgetary only. Enter your load and the autonomy you need.

-Usable battery energy to install (kWh)
-PV array (kWp)
-Transformer rating (kVA)
-Full-load current at 415 V (A)

Assumes 90% usable depth of discharge, 90% round-trip efficiency, 0.80 PV performance ratio, and the transformer loaded to 80% at peak. Final sizing needs a load study and site data.

Work

Real specifications, shown in full.

Client names stay private. The technical content does not.

Work sample

2000 kVA isolation transformer for an off-grid data centre

ScopeSpecification and quote comparison
Size2000 kVA, 3-phase, 60 Hz
Voltages415Y/240 V to 415Y/240 V
StatusRev 10 issued for EE review

The owner needed a transformer between solar and battery inverters and an off-grid data-centre load. The source side had to stay ungrounded and the load side grounded. We worked out the architecture, wrote the data sheet, and compared a vendor proposal against it. The biggest mismatch was an indoor NEMA 1 enclosure offered against an outdoor IP55 requirement.

ConnectionWye-wye (Yyn0), isolated windings; buried delta tertiary for heating and harmonics
Harmonic ratingK-8, with neutral pads rated 200% of phase current
EnclosureIP55 outdoor on skid base, filtered ventilation for a high-dust site, C4H corrosion finish
Taps1 above, 1 below at 5%, de-energized
TerminationsDouble lug sets per phase and neutral for phase-2 switchgear
Full-load currentAbout 2,782 A at 415 V
More projects

Project portfolio

Texas, USA

Off-grid mobile data centre

Solar PV and battery storage powering a mobile data centre with no grid connection.

Arkansas, USA

DC-coupled, grid-connected solar and storage

Grid-connected solar with DC-coupled batteries, interconnected with the local utility.

Virginia, USA

Backup battery for critical data-centre load

Battery power that keeps critical data-centre load running through grid outages.

Nevada and California, USA

500 MWdc grid-scale project with 160 MWh of storage

Utility-scale project spanning two states.

Visayas, Philippines

Battery for ancillary services and energy arbitrage

Storage earning revenue from grid services and from buying low and selling high.

Commercial and industrial

Backup power for vaccine storage

Battery backup for critical load, so vaccines stay cold through outages.

Commercial and industrial

Research facility

Solar and storage supporting a research facility.

Commercial and industrial

Hotels

Solar and storage for hotels.

Residential

Residential systems

Optimized for low cost and short payback.

Spec library

Data sheets you can send to a vendor.

Every parameter stated, every line tagged so your engineer knows what is fixed and what still needs a decision.

Transformer

2000 kVA outdoor dry-type isolation transformer

415Y/240 V Yyn0, K-8, IP55, aluminum windings, class 220 °C. Rev 10.

Storage

Battery container and cabinet checklist

Ratings, cycle life, cooling, fire protection, communications and EMS interface.

Inverters

PV inverter selection sheet

Voltage, MPPT range, neutral handling, auxiliary power and plant controller interface.

Key parameters in the transformer sheet

ParameterValue
Rating2000 kVA, 3-phase, 60 Hz
Impedance5.5% ±7.5% tolerance
Insulation / riseClass 220 °C, 150 °C average winding rise
BIL10 kV on both windings
LossesNo-load 3,000 W or less; load 13,000 W or less at 75 °C
Efficiency99.28% or better at 35% load
Sound66 dBA
ShieldAluminum electrostatic shield with accessible ground; copper optional
CoolingNatural air; optional dual-stage forced air under thermostat control
Site limits40 °C maximum ambient, 1000 m maximum altitude
StandardsIEC 60076 series, IP55 per IEC 60529; no UL listing required

The full sheet also covers terminations, accessories, factory tests and quote requirements. Request the PDF or Word version.

About

Engineers who also buy the equipment.

BA6 Project Solutions Inc. sits between the people who design power systems and the people who build them. We write specifications like an engineering firm and source equipment like a supplier, so the two stay in step.

Offices

Where we are

Philippines: Bonifacio Global City (BGC), Metro Manila.
United States: Sheridan, Wyoming.

How we operate

Vendor neutralWe recommend what meets the spec, not what pays the highest margin.
Numbers statedEvery claim on a data sheet is tagged: set, estimated, or open.
Anonymized by defaultTender drawings go out without client identifiers.
Contact us

Tell us about the site.

Send us a short email. The more you tell us, the faster we can come back with real questions and a budget range.

The button opens your email app with a short checklist filled in. You can also write to us directly at info@ba6projectsolutions.com.

Helpful to include

Who you areYour name, company, and whether you are an EPC, developer, site owner or operator.
The siteLocation, peak load, system voltage and frequency.
The systemBattery autonomy needed, and whether you are looking for engineering, equipment, financing, or all three.
TimingWhen you need it energized.

Offices

Philippines

Bonifacio Global City

Metro Manila

United States

Sheridan, Wyoming

United States office